$ File: "Box 1 (TC EtherNet_IP Slave)_20211113_103225.eds" Electronic Data Sheet generated by Beckhoff EDS - Builder 3.1 $ Copyright (C) 2012 by Beckhoff Automation GmbH [File] DescText = "TC GENERIC EDS (Device 1 (TC3 EIP Adapter), Box 1 (TC EtherNet/IP Slave))"; CreateDate = 11-13-2021; CreateTime = 10:33:08; ModDate = 11-13-2021; ModTime = 10:33:08; Revision = 1.6; HomeURL = "http://www.beckhoff.com"; [Device] VendCode = 108; VendName = "Beckhoff Automation GmbH & Co.KG"; ProdType = 12; ProdTypeStr = "Communications Adapter"; ProdCode = 6280; MajRev = 3; MinRev = 1; ProdName = "Box 1 (TC EtherNet/IP Slave)"; [Device Classification] Class1 = EtherNetIP; [Params] Param1 = 0,,,0x0000,0xC8,4,"Assembly 1: Output CycleTime/RPI (O->T)","","Assembly 1",1000,3200000,10000,,,,,,,,,; Param2 = 0,,,0x0000,0xC8,4,"Assembly 1: Input CycleTime/RPI (T->O)","","Assembly 1",1000,3200000,10000,,,,,,,,,; Param3 = 0,,,0x0000,0xC7,2,"Assembly 1: Output Size (O->T)","","Assembly 1",4,502,20,,,,,,,,,; Param4 = 0,,,0x0000,0xC7,2,"Assembly 1: Input Size (T->O)","","Assembly 1",4,502,20,,,,,,,,,; Param5 = 0,,,0x0000,0xD1,1,"Assembly 1: Input Data (T->O)","","Assembly 1: Input Data (T->O)",,,0,,,,,,,,,; Param6 = 0,,,0x0000,0xD1,1,"Assembly 1: Output Data (O->T)","","Assembly 1: Output Data (O->T)",,,0,,,,,,,,,; [Assembly] Object_Name = "Assembly Object"; Object_Class_Code = 0x04; Assem129 = "Assembly 1: Input Data(T->O)", "20 04 24 81 30 03", 502, 0x0001, ,, 4016,Param5; $ Assembly 1: Input Data (T->O) Assem130 = "Assembly 1: Output Data(O->T)", "20 04 24 82 30 03", 502, 0x0001, ,, 4016,Param6; $ Assembly 1: Output Data (O->T) [Connection Manager] Object_Name = "Connection Manager Object"; Object_Class_Code = 0x06; Connection1 = 0x84010002, $ Trigger and transport: class 1, cyclic, exclusive owner 0x44640405, $ Connection: unicast both ways or mcast T=>O, scheduled Param1,Param3,Assem130, $ O->T RPI, size, format Param2,Param4,Assem129, $ T->O RPI, size, format ,, $ config1 ,, $ config2 "Assembly 1: Inputs and Outputs (Exclusive Owner)", $ Connection Name "Assembly 1: Inputs and Outputs (Exclusive Owner)", $ help string "20 04 24 80 2C 82 2C 81"; $ Path Connection2 = 0x82010002, $ Trigger and transport: class 1, cyclic, input only 0x44640305, $ Connection: unicast/mcast, heartbeat, scheduled Param1,0,, $ O->T RPI, size, format Param2,Param4,Assem129, $ T->O RPI, size, format ,, $ config1 ,, $ config2 "Assembly 1: Inputs (Input Only)", $ Connection Name "Assembly 1: Inputs (Input Only)", $ help string "20 04 24 80 2C 89 2C 81"; $ Path Connection3 = 0x81010002, $ Trigger and transport: class 1, cyclic, listen only 0x44640305, $ Connection: unicast/mcast, heartbeat, scheduled Param1,0,, $ O->T RPI, size, format Param2,Param4,Assem129, $ T->O RPI, size, format ,, $ config1 ,, $ config2 "Assembly 1: Inputs (Listen Only)", $ Connection Name "Assembly 1: Inputs (Listen Only)", $ help string "20 04 24 80 2C 88 2C 81"; $ Path [Capacity] MaxCIPConnections = 8; MaxConsumersPerMcast = 8; TSpec1 = TxRx, 4, 1000; TSpec2 = TxRx, 500, 1000; [TCP/IP Interface Class] Object_Name = "TCP / IP Interface Object"; Object_Class_Code = 0xF5; Revision = 3; MaxInst = 1; Number_Of_Static_Instances = 1; Max_Number_Of_Dynamic_Instances = 0; [Ethernet Link Class] Object_Name = "Ethernet Link Object"; Object_Class_Code = 0xF6; Revision = 3; MaxInst = 1; Number_Of_Static_Instances = 1; Max_Number_Of_Dynamic_Instances = 0; InterfaceLabel1 = "Port 1"; InterfaceType1 = 2;